Tuesday, December 21, 2010

New creping doctor holder

Notes on the new creping doctor holder

· The backing blade only has two screws that hold it in place, one on each end.

· The backing blade is different than what we were using; we have a spare on order.

· This holder does not have a blue tube. It has a stainless rod instead.

· The blade cartridge slides all the way to the back and stops when it is in the right place. This is a different cartridge than we were using.

· Because the blade holder is heavier the blade pressure has been increased to 45 psi.

      Call if you have any questions. Gary