| Tons Produced | A Tons | B Tons | Hold Tons |
| 91.7 | 78.5 | 9.6 | 1.7 |
All B tons are caused by having the #1 uhle box closed.
Please only use a third vacuum as a means to help clean out the felt if needed. This should be a last resort and is not a long term solution if we want to keep the felt on for any reasonable time. Please first check the condition of machine rolls to see if there is build up , check all of the shower settings, uhle box conditions, and general machine operations before engaging a third vacuum pump. We had bad corrugation on the tending side that was cleared mostly up by just eliminating build up on the suction pressure roll.
Please check the pressure of the clarified water coming to us. It should be around 90 psi. We were unable to get the proper flooded nip flows because of low psi. Check and clean our filter bank and check if there is an increase in pressure. If you still do not have the pressure where it needs to be, call the pulp mill and tell them to check their side. Example-We only had 55 psi when I came in today. Our side cleaned them out and they were rather dirty. We still only had 65 psi. The pulp mill was informed and we soon had 90 psi. It was that easy.
The 3rd hands must try to make sure they are not hitting the cores staged up above the building reel with water. Hattiesburg North is having issues with tape that has pieces of core attached going into the middle of the rolls.
No comments: